Masterseal 1500 msds. Search by entering the brand or product name.
Masterseal 1500 msds It requires only the addition of clean water to produce a ready-to-use, ultra-rapid setting, plugging mortar. H372 Causes damage to organs (Lung) through prolonged or repeated application of MasterSeal M 200. BaSE COat In most cases a primer is not required for the MasterSeal system. H334 May cause allergy or asthma symptoms or breathing difficulties if inhaled. 3. Product code 30630252 Revision date 2019 June 22 Language English. 93 L) pails SDS details and previous versions (where available) Masterseal 900 Tan Manufacturer BASF Canada Inc. tOpCOat Apply MasterSeal TC 225 at 15 – 20 mils Sikaflex® NP 1 is a one-component, high-performance, non-priming, gun-grade, elastomeric polyurethane sealant. Sikalastic® M 205 is a low VOC one-component, moisture-curing polyurethane base coat for use in Sikalastic® Traffic 1500 and 2000 Low VOC deck coating systems. See separate Sikalastic® Aliphatic Top Coats data sheet for DecoQuartz® and DecoFlake® systems. 93 L) - MasterSeal M 200, (self-leveling and slope-grade): - 5 gallon (18. PRODUCT HIGHLIGHTS May 20, 2019 · SDS management, distribution & revision solutions - for every budget. Immediately back roll to level the coating and while the coating • MasterSeal Vehicular 2500 Low VOC • MasterSeal Pedestrian 1500 • MasterSeal Pedestrian 1500 Low VOC •Store in unopened containers in a cool, MasterSeal Pedestrian 2000 • MasterSeal Pedestrian 2000 Low VOC VOC CONTENT MasterSeal P 220 has the following g/L VOC contents less water and exempt solvents: • MasterSeal P 220: 400 g/L Download production information, safety data sheets, technical data sheets and more for each brand family. • It is the user’s responsibility to check the adhesion of the cured sealant on typical test joints at the project site before and during application. The product helps extend the pavement’s life by protecting it from water infiltration, UV radiation, and other environmental degradation factors. 659 (wet) B101. – MasterSeal TC 235, a low VOC, one component aliphatic, moisture curing polyurethane. 93 L) pails The BASF Product Safety Document Portal provides access to safety data sheets and other product safety information. Masterseal 590 - Free SDS search Oct 23, 2020 · SDS management, distribution & revision solutions - for every budget. Masterseal 900 Pbl 246 - Free SDS search Aug 31, 2020 · SDS management, distribution & revision solutions - for every budget. Allow the primer to dry before applying Sikaflex® HY 150. PRODUCT HIGHLIGHTS • MasterSeal Vehicular • MasterSeal Vehicular 1500 Low VOC • MasterSeal Pedestrian 1500 • MasterSeal Pedestrian 1500 Low VOC PACKAGING MasterSeal 914 – 1 pint can in case of 12 SHELF LIFE When properly stored, MasterSeal 914 products have the following shelf life: 1 pint: 2 Years STORAGE Store in unopened containers in a cool, clean, dry area YIELD See as MasterSeal NP 1 or NP 2. <br /> Can be applied by stiff brush, roller, or trowel, it forms a waterproof coating. 825 MacKay SikaTop®-550 Seal is a two-component acrylic modified cementitious coating that requires on site mixing to form product to waterproof and resurface concrete, masonry, and most other construction materials. Sikalastic® M 205 is VOC compliant Sikalastic® M 205 has strong adhesion properties Avoid application of Sikalastic® Pedestrian Traffic 1500 Low VOC when inclement weather is present or imminent. 5 million safety data sheets available online, brought to you by 3E. 1 (30606543/SDS_GEN_CA/EN) Pictogram: Signal Word: Danger Hazard Statement: H318 Causes serious eye damage. Sikalastic® Pedestrian Traffic 1500 Low VOC is not suitable for use where chained or metal-studded tires will be used. Refer to the technical data guides for MasterSeal P 179 and MasterSeal P 173. 0 (30639675/SDS_GEN_US/EN) Label elements Pictogram: Signal Word: Danger Hazard Statement: H319 Causes serious eye irritation. txt) or read online for free. 0 Revision Date: 01/28/2021 SDS Number: 000000247154 Date of last issue: - Date of first issue: 01/28/2021 2 / 14 Precautionary Statements : Prevention: P201 Obtain special instructions before use. Allow curing time of 72 hours before vehicular use and 48 hours before pedestrian use. 825 MacKay MasterSeal TC 255: • 209 g/L menos agua y excento de solventes Descripción MasterSeal Traffic 1500 es un sistema de impermeabilización compuesto por: • MasterSeal M 200, poliuretano de curado húmedo monocomponente • MasterSeal TC 225, poliuretano alifático de curado húmedo monocomponente • MAsterSeal TC 255 Tinta Base, consistiendo MasterSeal 581 wht also THOROSEAL WHITE Revision date : 2013/03/20 Page: 1/8 Version: 2. H317 May cause an allergic skin reaction. The mil thickness of all coats can also be verified by MasterSeal® Traffic 1500 (Formerly Sonoguard System) is a product in the Traffic Coatings category. Sikalastic® M 200 has strong adhesion properties Easy preparation reduces on-site labor costs MasterSeal Traffic 1500 waterproofing systems are composed of: MasterSeal M 200, a one-component, moisture-curing polyurethane SDS View; Regina Office. 1. Tool to form a 45 degree cant. Our team is ready to help! Download all Safety Data Sheets. H411 Toxic to aquatic life with long lasting effects. to applying MasterSeal TC 225. MasterSeal Traffic 1500 ideal for various vehicular or pedestrian traffic solutions MasterSeal ® Traffic 1500 (Low VOC) DESCRIPTION MasterSeal Traffic 1500 waterproofing systems are composed of: – MasterSeal M 205, a low VOC, one component, moisture curing polyurethane. MasterSeal 900 Cus - Free SDS search May 24, 2018 · SDS management, distribution & revision solutions - for every budget. Pour entire can of MasterSeal 915 (1/2 pint) into Jan 17, 2023 · Görüntüle BASF - MasterGlenium TC 1500 Görüntüle BASF - MasterSeal P 107 MSDS IZOCAM MW Panels-Turkce Vic-300 MasterSeal™ Butterfly Valve Series 761/461 Installation and Maintenance Manual . Search by entering the brand or product name. Masterseal 900 Tan - Free SDS search May 23, 2019 · SDS details and previous versions (where available) MasterSeal NP 100 Manufacturer BASF Canada Inc. The Sikalastic® TC 225 HT Tint Base product allows for a variety of colors in pedestrian applications. H401 Toxic to aquatic life. 93 L) pails - MasterSeal P 220: 4 gallon (15. Product: MasterSeal M 790 grey PART A (ID no. Embed MasterSeal 995 (or equivalent) into the Topcoat. 5. H402 Harmful to aquatic life. 4. For example, one pail of MasterSeal M 200 will cover an area approximately 2300 ft (28 m2), or a grid 30 by 10 ft (9 by 3 m) at 25 wet mils (0. TC 225 Masterseal is a revolutionary product designed to protect asphalt pavements from the elements. 03 020812900000000152 SYSTEM DATA SHEET Sikalastic® Pedestrian Traffic 1500 POLYURETHANE WATERPROOFING, TRAFFIC-BEARING MEMBRANE SYSTEMS FOR PEDESTRIAN AREAS. May 16, 2018 · SDS management, distribution & revision solutions - for every budget. Hazards Identification MasterSeal 550 Part B Version 1. • MasterSeal Traffic 1500 is not suitable for use where chained or metal-studded tires will be used. Sika provides solutions for even the most challenging requirements with its unique waterproofing product portfolio, contributing to efficient, long-lasting infrastructure, be it for drinking water facilities (fulfilling the most stringent drinking water approvals), tunnels, bridges, basements or balconies. Watch Sikalastic 726 Balcony One Shot in Action! Pedestrian traffic coatings refer to any walkable surface including footbridges, walkways, mechanical rooms, stadiums, plaza decks or balconies. APPLICATION INSTRUCTIONS SUBSTRATE QUALITY / PRE-TREATMENT Substrates must be structurally sound, clean, dry and MasterSeal CR 100 PART A Revision date : 2018/07/22 Page: 2/10 Version: 5. Basf Masterseal Traffic 1500 Tds Oct 2, 2024 · Masterseal TC 235: 1500 Traffic System 5 gal. Masterseal 1500 is a polyurethane waterproofing and traffic bearing membrane system consisting of: Masterseal M 205 Low VOC (Base Coat) Masterseal TC 235 Low VOC (Top Coat) Required Tools/Accessories for Masterseal 1500 application: Mixing Drill; Jiffy mixing paddle; Roller cage/roller covers; Spiked sandals for applying our MasterSeal Traffic 1500 system. 93 L) pails MasterSeal M 200 overlap the joint 3" (76 mm) on each side. See separate Sikalastic® Aliphatic Top Coats data sheet for DecoQuartz® and DecoFlake® systems. The MasterSeal 915 promotes the bond of base coat to substrates. May damage the unborn child. Product and Company Identification Company BASF CORPORATION 100 Park Avenue Florham Park, NJ 07932, USA 24 Hour Emergency Response Information CHEMTREC: 1-800-424-9300 BASF HOTLINE: 1-800-832-HELP (4357) 2. A light, uniform coating is sufficient for most surfaces. Masterseal 900 - Free SDS search SDS management, distribution & revision solutions - for every budget. 0 Revision Date: 02/11/2021 SDS Number: 960000009255 Date of last issue: - Date of first issue: 02/11/2021 2 / 9 ter or doctor. • MasterSeal M 200 — Surface preparation and application should be conducted as stated in our published product data guide. 8. . FIRE-FIGHTING MEASURES • MasterSeal Vehicular 1500 • MasterSeal Vehicular 2000 • MasterSeal Pedestrian 1500 • MasterSeal Pedestrian 2000 VOC CONTENT MasterSeal M 200 has the following g/L VOC contents less water and exempt solvents: • MasterSeal M 200: 196 g/L (self-leveling) 203 g/L (flash/slope) PACKAGING MasterSeal M 200 – 5 gallon (18. MasterSeal Traffic 1500 waterproofing systems are composed of: – MasterSeal M 205, a low VOC, one component, moisture curing polyurethane. Allow MasterSeal M 200 to cure overnight (16 hours minimum). Apply primer full strength with a brush or clean cloth. The Sikalastic® TC 225 HT is a one-component waterproofing coating and is UV-resistant. Do not apply Sikalastic® Pedestrian Traffic 1500 Low VOC to damp, wet, or contaminated surfaces. 93 L) pails • Avoid application of MasterSeal Traffic 1500 when inclement weather is present or imminent. Allow 5" excess fabric to be used as a hand hold while conducting the pull test. Tint Base version allows for a variety of colors in pedestrian applications. MasterSeal P 179. 6 mm). 8mm+ 2. MasterSeal NP 100 - Free SDS search May 12, 2019 · SDS management, distribution & revision solutions - for every budget. H332 Harmful if inhaled. H351 Suspected of causing cancer. Masterseal 590 - Free SDS search Feb 1, 2023 · SDS details and previous versions (where available) Masterseal AWB 900 Manufacturer BASF Admixtures Product code 000000699016, 000000000050500960 Revision date MasterSeal NP 150 wht also SONOLASTIC 150 VLM TECH WHITE Revision date : 2015/04/15 Page: 2/10 Version: 2. When cured, it forms a tough, resilient joint seal that resists penetration and abrasion and remains flexible when exposed to weather and aging. 3 with GS-1 MasterSeal 1500 Hardness 940DR 7 MOHS Read, understand and follow all Material Safety Data Sheets and product label MasterSeal® Traffic 1500 DESCRIPCIÓN MasterSeal Traffic 1500 es un sistema de impermeabilización compuesto por: – MasterSeal M 200 (Sonoguard Base Coat), poliuretano de curado húmedo monocomponente – MasterSeal TC 225 (Sonoguard Top Coat), poliuretano alifático de curado húmedo monocomponente – MasterSeal TC 225 Tinte Base Sikaflex® SL 2 is a multi-component, self-leveling, elastomeric polyurethane sealant that is mixed and poured in place. MasterSeal TC 235 is a low VOC, moisture-curing polyurethane top coat for use in MasterSeal Traffic 1500 Low VOC deck coating systems. Sikalastic® M 270 NP is a two-component polyurethane base coat for use in Sikalastic® Traffic 2500, 2530, 2575 and 2850 deck coating systems. 0 (30606091/SDS_GEN_US/EN) exposure Label elements Pictogram: Signal Word: Danger Hazard Statement: H319 Causes serious eye irritation. Expansion joints exceeding 1" (25 mm) wide should not be coated over with MasterSeal Traffic 1500 so that they can perform independently of the deck coating system. SECTION 5. MasterSeal® trafic vehicular systems from BASF are composed of the most advanced technology in the industry. The MasterSeal TC 225 Tint Base product allows for a variety of colors in pedestrian applications. Allow the MasterSeal TC 225 to fully cure. P202 Do not handle until all safety precautions have been read and understood. Apply MasterSeal TC 225 with Adhesion Promoter. pdf), Text File (. These systems are very durable to trafic, chemical exposure and harsh weather; however, there are circumstances which can exceed the limits of even the highest performance system. •Certain architectural metal finishes may require priming with MasterSeal P 173. 0mm 3. 06. H315 Causes skin irritation. Repair of the MasterSeal traffic system begins with ensuring that the substrate is sound, clean and dry, then is followed by the application of a MasterSeal traffic system to the affected area according to written recoat instructions MasterSeal M 200 overlap the joint 3" (76 mm) on each side. Product code 30605756 Revision date 2017 March 06 Language English. 93 L) pails MasterSeal® Vehicular Traffic 1500 DESCRIPTION MasterSeal Traffic 1500 is a waterproofing system consisting of: MasterSeal M 200, a one-component, moisture-curing polyurethane MasterSeal TC 225, a one-component aliphatic moisture-curing polyurethane N ote: MasterSeal TC 225 Tint Base is intended for pedestrian use only and is not suitable MasterSeal Traffic 1500 waterproofing systems are composed of: MasterSeal M 200, a one-component, moisture-curing polyurethane SDS View; Regina Office. Find submittal-ready datasheets, SDS, specs, ICC-ES reports. LIGHT TO MEDIUM TRAFFIC SYSTEM Primer Mastertop 1090 6-8m² litre MasterSeal M 200 0. over with MasterSeal Traffic 1500. It requires no mixing and typically requires no priming to bond to many materials, including concrete and masonry. Expansion joints exceeding 1" (25 mm) wide should not be coated over with MasterSeal M Pedestrian Traffic 1500 so that they can perform independently of the deck coating system. 1 (30605871/SDS_GEN_US/EN) 1. Where the coating system will be terminated and no wall, joint or other appropriate break exists, cut a ¼" x ¼" (6 x 6 mm) keyway into MasterSeal NP 1 Revision date : 2018/07/28 Page: 2/12 Version: 6. Allow to cure overnight. Application MasterSeal 590 INDUST also WATERPLUG Revision date : 2015/10/20 Page: 2/10 Version: 3. Product identifier MasterSeal M 790 grey PART A 1. • MasterSeal TC 225 — Apply 20 wet mils using a notched squeegee at 80 ft2/gallon. 65litres/ m² MasterSeal Aggregate – 2-3kg/ m² DFT 2. MasterSeal 550 PART A Version 1. 0 (30639623/SDS_GEN_US/EN) Label elements Pictogram: Signal Word: Danger Hazard Statement: H319 Causes serious eye irritation. Sikalastic® Vehicular Traffic 1500 is a moisture-curing polyurethane system. Relevant identified uses of the substance or mixture and uses advised against MasterSeal TC 225 is a moisture-curing polyurethane top coat for use in MasterSeal Traffic 1500 deck coating systems. 6 mm) MasterSeal M 200 using a proper notched squeegee at 60 ft2/gallon (1. MasterSeal NP 150 Tan - Free SDS search May 23, 2019 · SDS management, distribution & revision solutions - for every budget. Complete single and two component systems in Gray, Charcoal and Tan as well as optional high performance aliphatic top coats in clear, standard and custom colors offer application flexibility and decorative options. 7litres/ m² MasterSeal TC 225 0. 5 m2/L). 30672836/SDS_GEN_GB/EN) Date of print 26. Confine the application to the exposed substrate, and feather out over the existing coating, unless it is necessary to apply MasterSeal M 200 over the entire area. Free access to more than 4. Most important symptoms and effects, both acute and delayed : No symptoms known or expected. 2. 14 L) units in 5 gallon pails (18. SDS management, distribution & revision solutions - for every budget. The Read, understand and follow all Material Safety Data Sheets and product label information for this product prior to use. Extend the curing time in cool-weather conditions. Basf Masterseal Traffic 1500 Tds - Free download as PDF File (. Apply 25 wet mils (0. USES Stadiums Balconies Parking Garages Commercial Construction Building and Restoration Sikalastic® TC 235 is a low VOC, moisture-curing polyurethane top coat for use in Sikalastic® Traffic 1500 Low VOC deck coating systems. 0 (30606142/SDS_GEN_US/EN) Signal Word: Warning Hazard Statement: H319 Causes serious eye irritation. Pull the MasterSeal 995 at a 90 degree or greater angle, trying to pull the Oct 25, 2015 · MasterSeal ® 505 Ultra-rapid setting mortar to plug active water leaks in concrete and masonry DESCRIPTION MasterSeal 505 is a blend of hydraulic cements, well-graded sands and additives supplied in dry powder form. H373 May cause damage to organs (Liver, Kidney) through prolonged or repeated exposure. Sikalastic® Pedestrian Traffic 1500 December 2024, Version 01. 2. About the TC 225 Masterseal: Masterseal Traffic 1500. Masterseal 900 Pld 242 - Free SDS search 941DR 0. MasterSeal NP 150 Revision date : 2018/05/16 Page: 2/10 Version: 5. The Sikalastic® TC 235 is a one-component waterproofing coating and is UV-resistant. MasterSeal CR 195 - Free SDS search Advantages. PRODUCT DESCRIPTION Sikalastic® Pedestrian Traffic 1500 is a waterproofing system consisting of: Masterseal 1500: Traffic Coating System. Form a sealant cant into the corner at the junction of all horizontal and vertical surfaces (wall sections, curbs, columns). Technical Data Guide 7 07 18 00 Traffic Coatings MasterSeal Traffic 1500 ® Polyurethane waterproofing, traffic-bearing membrane systems for vehicular and pedestrian areas Formerly Sonoguard® Packaging - MasterSeal P 222: 5 gallon (18. H360 May damage fertility. MasterSeal TC 225 is a moisture-curing polyurethane top coat for use in MasterSeal Traffic 1500 deck coating systems. • MasterSeal Vehicular 1500 • MasterSeal Vehicular 2000 • MasterSeal Pedestrian 1500 • MasterSeal Pedestrian 2000 VOC CONTENT MasterSeal M 200 has the following g/L VOC contents less water and exempt solvents: • MasterSeal M 200: 196 g/L (self-leveling) 203 g/L (flash/slope) PACKAGING MasterSeal M 200 – 5 gallon (18. The • MasterSeal Vehicular 1500 • MasterSeal Vehicular 2000 • MasterSeal Pedestrian 1500 • MasterSeal Pedestrian 2000 VOC CONTENT MasterSeal M 200 has the following g/L VOC contents less water and exempt solvents: • MasterSeal M 200: 196 g/L (self-leveling) 203 g/L (flash/slope) PACKAGING MasterSeal M 200 – 5 gallon (18. Waterproof to help protect building interiors from dampness and moisture damage; Air barrier reduces air infiltration; Resistant to both positive and negative hydrostatic pressure, making Sika Thoroseal®-581 suitable for use below grade interior and exterior and in water treatment construction Usage Sikagard® AWB 600 FL is designed to prepare rough, porous concrete/masonry substrates for subsequent application of Sikagard® AWB fluid-applied air/water-resistive barrier products. How does MasterSeal Traffic 1500 work? MasterSeal Traffic 1500 waterproofing systems are composed of: • MasterSeal M 200, a one-component, moisture-curing polyurethane • MasterSeal M 205, a low VOC, one component, moisture-curing polyurethane • MasterSeal TC 225, a one-component aliphatic moisture-curing polyurethane MSDS-MasterSeal_912_(ex_MFlex_611) - Free download as PDF File (. MasterSeal NP 100 Tan - Free SDS search MasterSeal 915 is an adhesion promoter for base coats for use in MasterSeal Traffic 1500, 2000, 2500, 2530 and 2575 deck coating systems. Sealed joints 1" (25 mm) or less can be coated over with MasterSeal Pedestrian Traffic 1500. MasterSeal Traffic 1500 ideal for various vehicular or pedestrian traffic solutions • Repairable and recoatable to extend the useful life of the system • Four standard colors: gray, charcoal gray, tan and dark tan MasterSeal ® Traffic 1500 DESCRIPTION MasterSeal Traffic 1500 waterproofing systems are composed of: How does MasterSeal Vehicular Traffic 1500 work? MasterSeal Vehicular Traffic 1500 waterproofing systems are composed of: MasterSeal M 200, a one-component, moisture-curing polyurethane; MasterSeal M 205, a low VOC, one component, moisture-curing polyurethane; MasterSeal TC 225, a one-component aliphatic moisture-curing polyurethane Whether you have a question, need assistance, or want to share feedback, please fill out the contact form or find your local contact. MasterSeal CR 100 PART A Revision date : 2018/07/22 Page: 2/10 Version: 5. • Proper application is the responsibility of the user. Apply masking tape to the vertical On bare concrete, apply MasterSeal M 200 at 60 ft2 per gallon. 2020 SECTION 1: Identification of the substance/mixture and of the company/undertaking 1. MasterSeal NP 150 - Free SDS search Sikalastic® TC 225 HT is a moisture-curing polyurethane top coat for use in Sikalastic® Traffic 1500 deck coating systems. The SDS provides information and advice on the safe handling, storage and disposal of chemical products and con-tains physical, ecological, toxicological and other safety-related data. Pull the MasterSeal 995 at a 90 degree or greater angle, trying to pull the ALIPHATIC POLYURETHANE TOPCOAT FOR SIKALASTIC® TRAFFIC 1500 DECK COATING SYSTEMS PRODUCT DESCRIPTION Sikalastic® TC 225 HT is a moisture-curing polyurethane top coat for use in Sikalastic® Traffic 1500 deck coating systems. 0 (30605759/SDS_GEN_US/EN) Label elements Pictogram: Signal Word: Danger Hazard Statement: H319 Causes serious eye irritation. 2litres/ m² MasterSeal TC 225 0. 0 (51704986/SDS_GEN_US/EN) Label elements Pictogram: Signal Word: Danger Hazard Statement: H317 May cause an allergic skin reaction. The MSDS can Aug 6, 2015 · SDS management, distribution & revision solutions - for every budget. H335 May cause respiratory irritation. Sealed joints 1" (25 mm) or less can be coated over with MasterSeal Pedestrian Traffic 1500. Immediately backroll to level MasterSeal M 200. MasterSeal M 200 is a polyurethane base coat for MasterSeal Traffic 1500 and 2000 deck coating systems RS Components is the leading distributor of can often damage the MasterSeal traffic system and the concrete or wood surfaces below. Notes to physician : Treat symptomatically. 65litres/ m² MasterSeal Aggregate – 1-2kg/ m² DFT 1. Sikalastic® M 200 is a one-component, moisture-curing polyurethane base coat for use in Sikalastic® Traffic 1500 and 2000 deck coating systems. The MasterSeal TC 225 is a one-component waterproofing coating and is UV-resistant. Sika offers you to download a single document or add selected documents into the basket for a zip download. MasterSeal NP 150 Med Brz Revision date : 2018/05/23 Page: 2/10 Version: 4. HEAVY DUTY TRAFFIC SYSTEM POLYURETHANE BASE COAT FOR SIKALASTIC® TRAFFIC 1500 AND 2000 DECK COATING SYSTEMS PRODUCT DESCRIPTION Sikalastic® M 200 is a one-component, moisture-curing polyurethane base coat for use in Sikalastic® Traffic 1500 and 2000 deck coating systems. The Sikalastic® TC 235 Tint Base product allows for a variety of colors in pedestrian applications. Very porous surfaces may require a second coat of MasterSeal P 179; however, do not over-apply. MasterSeal 350 PART A Revision date : 2014/04/29 Page: 2/9 Version: 3. chart to determine the quantity of MasterSeal Traffic 1500 needed for each grid to arrive at the required mil thicknesses. The TC 235 is a one-component waterproofing coating and is UV-resistant. • Do not apply MasterSeal Traffic 1500 to damp, wet, or contaminated surfaces. MasterSeal M 200 1. Data Sheets (SDS) before using any products. Prime with MasterSeal P 173 and apply a ½–1" (13–25 mm) wide bead of MasterSeal NP 1 or MasterSeal NP 2 sealants. slhb gtywpj xjmgzva vczxpf viwqmh djtuga rdiie gsb ams puwnro jpt iluxk nrpppw jgjw fzl